PV system solution, type 2, with MC4 connector and switch disconnector for inverter with 1 MPP tracker, 1,000 V DC

Item no. 5088501 | EAN 4012196792207

IP66
Product description

Product description

System solution, type 2, with MC4 connector and switch disconnector for inverter with 1 MPP tracker, 1,000 V DC

• Varistor arrester, connectable with cut-off unit in error-resistant Y circuit to VDE 0100-712 (50539-12)
• Low DC voltage protection level: < 4.0 kV (Voc max = 1,000 V DC with V20-C/0-500PV)
• Switch-disconnector (1,000 V; 8 A) for safe switch-off of the DC string line
• One PV string input (MC4 plug connector) at an MPP input, up to 30 A DC per terminal
• Pre-mounted in polycarbonate housing (IP66), UV-resistant for use outside

For DC protection of the inverter in photovoltaic systems.

If there is a danger of condensation forming through wind, ice, temperature or sunlight, further measures may be necessary!
  • 5-year warranty
  • Communautés Européennes, EC declaration of conformity according to EC directives
  • Protection device to DIN EN 61643-11 or IEC 61643-11
  • Transition from LPZ 1 to LPZ 2
  • Installation electrotechnical expertise
Technical data

Technical data

Colour Light grey; RAL 7035
DC network form no
Depth 125 mm
Dimension 1000V DC
Equipped with load-break switch no
Installation type Pre-mounted in the housing
Integrated back-up fuse no
IT network form no
Lightning protection zone LPZ 1→2
Material Polycarbonate
Max. Input current per string 30 A
Max. Input voltage DC 1000 V
Max. Output current 30 A
Max. PV voltage 1000 V
Maximum back-up fuse 125 A
Maximum continuous voltage DC 1000
Maximum discharge current (8/20 μs) 40 kA
Monitoring function no
Network form Other
Nominal discharge current (8/20 µs) 20 kA
Number of cable entries 4
Number of inputs 1
Number of string inputs 1
Operating temperature, max. 80 °C
Operating temperature, min. -40 °C
Other network form no
Permitted temperature range, max. 60 °C
Permitted temperature range, min. -25 °C
Pole version 3
Protection rating IP66
Protection rating IK code IK05.
Remote signalling no
Response time <25 ns
Signalling on device Visual
SPD to EN 61643-11 Type 2
SPD to IEC 61643-1 Class II
Test class, type 1 no
Test class, type 2 yes
Test class, type 3 no
TN network form no
TN-C network form no
TN-C-S network form no
TN-S network form no
TT network form no
Type of entry MC4
Version for 3-pole for PV systems

Dimensions

Height 191 mm
Width 240 mm

Connectivity options

Max. mains-side overcurrent protection 125
All types

All types

Types Protection rating Item no. Quantity SSU
PVG-C1000S100 IP66 5088554
1 piece
PKV-C1000ST100 IP66 5088501
1 piece